When selecting andalusite bricks, many people ask only one question—"how much andalusite has been added?"—assuming that a higher content equates to better quality. This is a common misconception. The proportion of andalusite is just one parameter; bricks of different grades and compositions vary significantly in their key properties and suitability for specific operating conditions. Choosing a grade that is too low will result in insufficient durability, while choosing one that is too high leads to unnecessary costs.
To select a suitable andalusite brick, follow three steps: First, determine the class; then, focus on key indicators; and finally, match them with the operating conditions. — this way, you’ll be able to choose the right model.


Classification of andalusite bricks
Kerui Refractory typically classifies andalusite bricks into three grades based on the andalusite proportion, alumina content, and performance characteristics. Each grade corresponds to a specific level of operating conditions:
Standard andalusite brick
The andalusite content is approximately 8–15%, the Al₂O₃ content is 55–60%, and the continuous operating temperature is 1300–1400°C. This is an entry-level product offering the best price-to-performance ratio; its specifications are slightly superior to those of standard high-alumina brick. It is suitable for secondary, medium-temperature areas subject to some temperature fluctuations—such as the middle and lower sections of hot blast stoves, the high-temperature zone of cement kiln preheaters, and the medium-temperature gas ducts of industrial boilers.
Standard andalusite brick
The andalusite content is approximately 15–25%, the Al₂O₃ content is 60–70%, and the continuous operating temperature is 1400–1500°C. This is the primary model in terms of usage volume in industrial projects. It offers a balance of creep resistance and thermal shock resistance, making it suitable for most critical medium- and high-temperature applications—such as the middle section of a blast furnace shaft, hot blast stove regenerators, cement kiln decarbonizers, medium-temperature furnaces, and more.
High-quality andalusite brick
The andalusite content exceeds 25% (with corundum particles added in some formulations), the Al₂O₃ content is over 70%, and the continuous service temperature approaches 1500°C. It offers superior creep resistance, corrosion resistance, and high-temperature strength. This is a high-performance product designed for the most demanding conditions, including high temperatures, heavy loads, and intense abrasive wear. Examples of applications include hot-blast stove combustion chambers, high-temperature reactor linings, and the upper shaft of blast furnaces.


Key indicators for selecting andalusite bricks
Do not rely solely on the andalusite content. The following three indicators also determine application effectiveness:
High-temperature creep rate
Evaluation is typically performed at 1400°C over a period of 50 hours. The lower the value, the less the brick deforms under prolonged exposure to high temperatures. This is a critical parameter for andalusite bricks; it requires particular attention in the case of furnaces operating in continuous mode.
Thermal stability (number of cycles)
This is often measured by the number of water-cooling cycles at 1100°C. The more cycles the brick withstands, the greater its resistance to alternating heating and cooling. For periodic furnaces involving frequent start-ups and shutdowns, this parameter should be the primary consideration.
Apparent porosity and bulk density
Bricks with low porosity and appropriate density possess a denser structure and offer better resistance to abrasive wear and slag penetration. However, density need not be maximized; a balance with thermal shock resistance must be struck, depending on operating conditions.
Industry recommendations for selection
-
Metallurgical industry: For key components of blast furnaces and hot blast stoves, select the standard or high-quality grade, paying particular attention to creep resistance and thermal stability; for secondary, medium-temperature sections, the ordinary grade is sufficient.
-
Construction materials industry: For the cement kiln's precalciner and preheater, select a standard grade, prioritizing resistance to alkali corrosion and stability under temperature fluctuations; there is no need to blindly aim for a high grade.
-
Chemical industry: For the medium-temperature zones of medium- and high-temperature reactors and gasifiers, select the standard grade, which combines corrosion resistance and heat resistance.
-
Energy: For the medium-temperature sections of circulating fluidized bed boilers, choose the standard grade; its resistance to abrasive wear and temperature fluctuations is superior to that of conventional high-alumina brick.